At the form boundary, there is no place for entrapped
air to escape. As such, immersion vibrator can not expel the air from form
boundary. This is the reason behind doing “slicing” along the form by means of
a flat plate on edge. “Slicing” removes the air entrapped air in the concrete
layer along the form.
Absorptive linings offer an alternative but expensive
option.
|